Cassette fan coils with EC motor

DIVA-XLI DIVA-XLI SWING

Cooling capacity: 12.6÷15.1 kW

Heating capacity: 13.4÷16.4 kW

WEBCODE: DIXI1 DIXS1

Product benefits

  • Innovative design for large environments
  • ABS ceiling panelling with manual or motorised fins and filter option ePM1-55%
  • Consumption reduced with EC motor
  • Touch controls
  • Set-ups for 2-, 4-pipe installations or 2 pipes with electrical resistance
  • 2 or 3-way, ON/OFF electrovalves and pre-mounted controls on board
Inverter_logo-\\ITRHREPOWEB\Archivio_immagini\LOGHI\inverter\Logo INVERTER 2.ai
  • IntCert1
  • Eurovent_logo

Cassette-type fan coil units



Construction features

• Fan coils: cassette-type for installation in false ceilings, with air return and delivery directly in the room, composed of a buffer ceiling unit.
DIVA-XLI
• Unit complete with:
- Heat exchanger: finned coil.
- Radial fan;
- Inverter brushless EC motor.
- Structure: self-supporting, in galvanised sheet steel complete with an additional condensate drain pan and pump to lift the condensate (maximum head 650 mm).
• Buffer ceiling (PLP or PLP/PM1 accessory): in ABS polymer (RAL 9003) with manually adjustable delivery fins and return grille.
DIVA-XLI SWING
• Unit complete with:
- Heat exchanger: finned coil.
- Radial fan;
- Inverter brushless EC motor.
- Structure: self-supporting, in galvanised sheet steel complete with an additional condensate drain pan and pump to lift the condensate (maximum head 650 mm).
- SWING advanced control for motorised fins integrated in the unit.
• Buffer ceiling (PLP/S or PLP/S/PM1 accessory): in ABS polymer (RAL 9003) with return grille, filter, IR receiver and motorised delivery fins.


Construction set-ups

Type of unit
2T - Single main coil
4T - Double main coil and additional
RE - Single main coil and supplementary electrical resistance.


ACCESSORIES

DIVA-XLI
• PLP- ABS Ceiling panelling (RAL 9003), with regenerable filter (G0).
• PLP/PM1 - ABS Ceiling panelling (RAL 9003), with filter ePM1-55% (F7).

DIVA-XLI SWING
• PLP/S- ABS Ceiling panelling (RAL 9003), with motorised fins and regenerable filter (G0).
• PLP/S/PM1- ABS Ceiling panelling (RAL 9003), with motorised fins and filter ePM1-55% (F7).
DIVA-XLI; DIVA-XLI SWING
➔❖ 3-way ON/OFF electrovalve for 2 and 4-pipe systems.
➔❖ 2-way ON/OFF electrovalves for 2 and 4-pipe systems.
• Circular connector for air distribution at a distance from the unit.
• Primary air kit.
• Casing for in view installation.
• 3-way ON/OFF electrovalve for in view casing.


CONTROLS

DIVA-XLI
STANDARD control for DIVA_XLI
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


Advanced LIT-TOUCH controls

➔ Flush LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ LIT-Touch remote control and receiver for ceiling panelling or wall mounting installation, with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔ Additional board with 2 digital outputs that can be configured.
➔ On board air temperature probe.
➔ RS485 serial board for serial communication with other devices (Modbus RTU protocol).
DIVA-XLI SWING
SWING advanced control for motorised fins integrated in the unit.
➔ Control panel flush with the display.
➔ Remote control.
➔ Wall mounting receiver with probe and LED.

Key: ❖ Factory fitted
➔ Supplied separately

DIVA-XLI - DIVA-XLI SWING
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
RE electrical resistance kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHT
Box - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Box - Weight kg
PLP Ceiling panelling - Weight kg
DIVA-XLI - DIVA-XLI SWING
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) [EN1397] kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHT
Box - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Box - Weight kg
PLP Ceiling panelling - Weight kg
130 150
12,6 15,13
9,43 11,38
6,36 7,86
13,39 16,4
9,59 11,86
6,18 7,82
15,84 19,57
11,42 14,07
7,39 9,33
23.45 30.67
17.02 20.84
10.34 13.6
3 3
1905 2480
1290 1650
790 1025
58 64
49 55
38 44
49 55
40 46
29 35
93 183
35 64
13 21
230-1-50 230-1-50
130 150
869 x 304 x 869 869 x 304 x 869
1017 x 91 x 1017 1017 x 91 x 1017
42 42
7,5 7,5
130 150
11,61 13,59
8,86 10,59
6,07 7,45
10,55 12,17
8,40 9,80
6,01 7,19
12,04 13,89
9,58 11,18
6,84 8,20
1905 2480
1290 1650
790 1025
58 64
49 55
38 44
49 55
40 46
29 35
93 183
35 64
13 21
230-1-50 230-1-50
130 150
869 x 304 x 869 869 x 304 x 869
1017 x 91 x 1017 1017 x 91 x 1017
42 42
7,5 7,5

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12℃.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.

Performance refers to the motor’s input signal: 10V - 5V - 1V at MAX - MED - MIN speed.