Electa-ECOS-T
MHAITI 104÷110 + IUT 06-10
Cooling capacity: 3.1÷6.5 kW
Heating capacity: 4÷9.5 kW
WEBCODE: EEST1
Product benefits
- Low GWP R32 refrigerant
- Energy class A+++
- Temperature of the produced water up to 60°C
- Domestic hot water production from –25°C to +45°C outdoor air
- Floor indoor unit complete with circulator, expansion tank, 3-way valve, DHW tank and electrical resistance.
- Touch-screen control panel.
- APP for managing the unit via smartphone (iOS and Android)


Two-section reversible air-water heat pumps with integrated tank for domestic hot water. Range with hermetic rotary DC Inverter compressors and R32 refrigerant gas.
Construction features
MHAITI outdoor unit
• Compressor: hermetic, twin rotary DC Inverter with steam injection, complete with thermal protection and casing heater
• Expansion valve: electronic.
• Cooling circuit with economiser
• Air side heat exchanger: finned coil with copper pipes and aluminium-manganese fins with Golden Fin anti-corrosion treatment in epoxy resin and hydrophilic treatment.
• Fan: axial type impeller with DC brushless motors, equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
• Structure: made of galvanised and painted steel plate RAL9002, complete with condensate drain pan and unit base antifreeze heater.
IUT indoor unit
Hydronic module for floor installation:
• Structure: made of galvanised and painted steel plate.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater.
• Pump unit complete with: EC circulator, automatic air vent valve, safety valve, flow switch, expansion tank, pressure gauge, water filter.
• 3-way valve for the production of domestic hot water.
• Supplementary electrical resistance system side.
• Domestic hot water buffer tank, complete with water temperature probe, anode and electrical resistance (3 kW).
• Control: electronic with microprocessor and touch-screen control panel for integrated management of the heat pump and the heating system, according to the various requirements relating to the use of the energy sources:
- Domestic hot water production.
- Rapid heating function for domestic hot water.
- Anti-legionella cycle function, with activation timer.
- Auxiliary or supplementary heat source management.
- Operation in silent mode with timer.
- Weekly and daily time bands.
- Holiday mode and antifreeze function.
- Power consumption limiting function.
- 2-way on/off valve management for shutting off a part of the system, in heating or cooling mode.
- Management through room thermostat, as an alternative to the touch-screen panel.
- Unit activation from external contact (remote ON/OFF).
• Unit complete with:
- Outdoor temperature probe for set-point compensation.
- Remote ambient air temperature probe, for managing the unit according to the ambient set-point.
- Communication cable between outdoor and indoor units.
• RS485 interface for serial communication with other devices (Modbus RTU protocol).
• iOS and Android APP for managing the unit via smartphone and tablet.
Version
T - High efficiency.
Models
MHAITI+IUT: 2-section air-water heat pump.
MHAITI outdoor unit | ||
IUT indoor unit | ||
❶ | Heating capacity | kW |
❶ | Absorbed power | kW |
❶ | C.O.P. | |
❷ | Heating capacity | kW |
❷ | Absorbed power | kW |
❷ | C.O.P. | |
❸ | Cooling capacity | kW |
❸ | Absorbed power | kW |
❸ | E.E.R. | |
❹ | Cooling capacity | kW |
❹ | Absorbed power | kW |
❹ | E.E.R. | |
❺ | Sound pressure (external unit) | dB(A) |
❸ | Available circulator head | kPa |
DHW tank capacity | L | |
Electrical supply | V-ph-Hz | |
Internal unit electrical resistance | kW | |
Refrigeration lines max Height difference / length | m / m | |
DIMENSIONS AND WEIGHTS | ||
MHAITI outdoor unit | ||
L - Width | mm | |
H - Height | mm | |
P - Depth | mm | |
Weight | kg | |
IUT indoor unit | ||
L - Width | mm | |
H - Height | mm | |
P - Depth | mm | |
Empty weight | kg | |
ENERGY PERFORMANCE | MHAITI | |
IUT | ||
AMBIENT HEATING - Average application temperature 55°C | ||
③ | Pdesignh (EN 14825) | kW |
③ | SCOP (EN 14825) | |
④ | ηs | % |
④ | Energy class | |
WATER HEATING | ||
Load profile | ||
⑤ | ηwh | % |
⑤ | Energy class | |
104 | 106 | 108 | 110 |
6 | 6 | 10 | 10 |
4 | 5.9 | 8 | 9.5 |
1.02 | 1.51 | 2.14 | 2.64 |
3.92 | 3.91 | 3.74 | 3.6 |
4 | 6 | 8 | 9.5 |
0.78 | 1.2 | 1.7 | 2.07 |
5.13 | 5,00 | 4.71 | 4.59 |
3,2 | 4,1 | 5.3 | 6.5 |
0,94 | 1,28 | 1.73 | 2.27 |
3.42 | 3.2 | 3,06 | 2.86 |
3.8 | 5.8 | 7,0 | 8.5 |
0.82 | 1.32 | 1.75 | 2.24 |
4.63 | 4,40 | 4,00 | 3.79 |
37 | 37 | 41 | 42 |
73 | 70 | 66 | 58 |
185 | 185 | 185 | 185 |
230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 |
2 x 1,5 | 2 x 1,5 | 2 x 3,0 | 2 x 3,0 |
20 / 15 | 20 / 15 | 25 / 15 | 25 / 15 |
104 | 106 | 108 | 110 |
975 | 975 | 980 | 980 |
702 | 702 | 788 | 788 |
396 | 396 | 427 | 427 |
55 | 55 | 82 | 82 |
6 | 6 | 10 | 10 |
600 | 600 | 600 | 600 |
1750 | 1750 | 1750 | 1750 |
600 | 600 | 600 | 600 |
209 | 209 | 209 | 209 |
104 | 106 | 108 | 110 |
6 | 6 | 10 | 10 |
5 | 5 | 7 | 8 |
3,27 | 3,25 | 3,31 | 3,25 |
128 | 127 | 129 | 127 |
A++ | A++ | A++ | A++ |
L | L | L | L |
101 | 101 | 89 | 89 |
A | A | A | A |
Data at the following conditions: |
|
❶ |
Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. |
❷ |
Air: 7°C D.B. - 6°C W.B. - Water: 30/35°C. |
❸ |
Air: 35°C D.B. - Water: 12/7°C. |
❹ |
Air: 35°C D.B. - Water: 23/18°C. |
❺ |
In open field (Q = 2) at 5 m from the unit. |
❻ |
Weight refers to the most complete set up. |
Performance according to EN 14511 |
|
③ |
In Average climatic conditions. |
④ |
Seasonal energy efficiency: ambient heating in Average climate (EU Regulations No.811/2013 and No.813/2013) |
⑤ |
Water heating energy efficiency in Average climate (+7°C). (Regulations (EU) No.811/2013 and No.813/2013) |