Compact-Y MD

TCAEY 238÷265 / THAEY 233÷265

Cooling capacity: 32.3

64.6 kW :

Heating capacity: 37.8

68.3 kW:

WEBCODE: CY011

Product benefits

  • 3 capacity steps (mod. 245-265)
  • HT65 version for 65°C water production (°)
AdesivoAfP_logo-\\ITRHREPOWEB\Archivio_immagini\LOGHI\adaptive\Etichetta AFplus bianco.tif
  • SoloRaffr_logo
  • PdC_logo
  • Install_EST_logo
  • R410A_logo
  • Eurovent_logo

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant gas.



Construction features

• Compressor: hermetic, rotary scroll type, complete with thermal protection and casing heater. 3 capacity steps with high efficiency at partial loads for models 245-265.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Air side heat exchanger: finned coil with copper pipes and aluminium fins, complete with protection grilles.
• Fan: external rotor helical type electric fan equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan speed regulation.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted sheet steel.
• The unit is also complete with:
- Master/Slave control up to 4 units in parallel;
- clock board.


Models

• TCAEY: unit designed for cooling only.
• THAEY: heat pump unit.


PUMP set-up

• Pump unit complete circulator, single or double electric pump, including an automatic actuation pump in standby (mod. 245-265), expansion tank, air bleed valves, safety valve and water side pressure gauge.

TANK&PUMP set up
• Pump unit complete inertial buffer tank, circulator, single or double electric pump, including an automatic actuation pump in standby (mod. 245-265), expansion tank, air bleed valves, safety valve and water side pressure gauge.


Factory fitted accessories

• Soft-start device.
• Silenced set up.
• 15% desuperheater.
• 100% heat recovery unit.
• Condensing control with fans with EC motor.
• Refrigerant circuit high and low pressure gauges (mod. 245-265).
• Buffer tank antifreeze heater.
• Electric pump antifreeze heater (mod. 245-265).
• Forced limit of power consumption.
• Refrigerant leak detector.
• Digital input for double set-point
• 4-20 mA analogue signal for shifting set-point.
• Energy parameter measuring device.
• Low water set-point temperature.
• Pre-painted copper/coils or copper/copper coils.


Separately supplied accessories

• Outdoor air temperature probe for set-point compensation.
• Additional electrical resistance for heat pump, managed by regulation.
• Rubber anti-vibration mounts.
• Water filter.
• Remote keypad with display.
• Interfaces for serial communication with other devices.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.



TCAEY MODEL (P1 set up)
Cooling capacity kW
Absorbed power kW
E.E.R.
THAEY MODEL
Heating capacity kW
Absorbed power kW
C.O.P.
Cooling capacity
E.E.R.
TCAEY-THAEY MODEL
Sound pressure dB(A)
Silenced setup sound pressure dB(A)
Scroll/step compressor n.
Circuits no.
Buffer tank water content (TANK&PUMP) l
Available nominal head of standard electric pump (TCAEY) kPa
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - Width mm
H - Height mm
P - Depth mm
TCAEY weight kg
THAEY weight kg
SEASONAL ENERGY PERFORMANCE
TCAEY MODEL SEASONAL PERFORMANCE IN COOLING MODE (P1 set up)
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
THAEY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
Energy class
233 238 245 250 260 265
- 39,4 44,8 51,9 59,8 64,6
- 12,83 17,43 19,73 22,15 24,01
- 3,07 2,57 2,63 2,7 2,65
37,8 42,1 48,1 56,2 62,6 68,3
12,54 13,19 16,82 18,97 20,86 23,71
3,01 3,19 2,86 2,96 3 2,88
32,3 38,5 42,3 50,3 57,8 61,6
2,59 2,95 2,49 2,68 2,64 2,54
233 238 245 250 260 265
54 54 56 56 57 57
51 51 53 53 54 54
2/2 2/2 2/3 2/3 2/3 2/3
1 1 1 1 1 1
80 150 150 150 150 150
106 87 113 102 87 74
400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
233 238 245 250 260 265
1660 2315 2315 2315 2315 2315
1570 1570 1570 1570 1570 1570
1000 1000 1000 1000 1000 1000
- 625 725 750 775 820
475 645 745 770 795 840
233 238 245 250 260 265
- 39,4 44,8 51,9 59,8 64,6
- 4,26 4,24 4,35 4,31 4,27
- 167 167 171 170 168
36 41 49 56 62 70
3,72 3,72 3,61 3,58 3,56 3,66
146 146 141 140 140 144
A+ A+ A+ A+ A+ A+

Data at the following conditions:

Air: 35°C - Water: 12/7°C.

Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C.

In open field (Q = 2) at 5 m from the unit.

Weight refers to the most complete set up.

Performance according to EN 14511

Low temperature application (7°C)

Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

In Average climatic conditions, low temperature application (35°C)

Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)