Fan coils with EC motor

BRIO-I SLIM

Cooling capacity: 1.0÷4.0 kW

Heating capacity: 1.1÷4.6 kW

WEBCODE: BRIS1 ACFCS

Product benefits

  • Exclusive design with thin profile.
  • Silent operation.
  • Excellent room comfort with continuous regulation of the fan speed.
  • Low consumption with standard EC motor.
  • Versions with cabinet and recessed installation with front radiant function.
  • Touch control, on board or wall-mounted
Inverter_logo GreenLine_logo
  • IntCert1
  • CE_logo
  • Eurovent_logo

Floor and ceiling fan coil units with cabinet for recessed wall or false ceiling installation



Construction features

• Heat exchanger: finned coil with Eurokonus ¾” left-hand connections; right-hand connections with accessory supplied separately.
• Tangential fan with constant speed regulation EC electronic motor and low-consumption micro-fans in the version with radiant function.
• Cabinet version structure: covering cabinet consisting of pre-painted sheet metal central panel and sides made of ABS polymer (or pre-painted sheet metal for 4-pipe systems), colour RAL9003 with matt finish, upper delivery grille in painted aluminium, silver grey colour.
Complete unit with vertical condensate drain pan and additional one with natural drainage, and regenerable filter.
• Recessed version structure: in galvanised sheet steel, complete with vertical condensate drain pan and additional horizontal one with natural drainage, and regenerable filter.


Versions

• MVP - Vertical unit with cabinet for wall mounting installation or with feet standing on the ground; ceiling installation with accessory supplied separately (KVXO)
• IXP - Recessed horizontal/vertical unit for false ceiling installation or wall installation.
• MVR - Vertical only unit with cabinet and front radiant function, for wall mounting installation or with feet standing on the ground.
• IVR - Vertical only recessed unit with front radiant function, for wall formwork installation.


Construction set-ups

Type of system
2T - 2-pipe systems
4T - 4-pipe systems with additional water heating coil (MVP and IXP versions only).


Accessories

➔ Cable for water connections on the right side.
➔ Eurokonus / Gas connection straight fitting.
➔❖ 2 -way ON/OFF solenoid valves for 2 and 4-pipe systems.
➔❖ 3 -way ON/OFF solenoid valves for 2 and 4-pipe systems.
➔ UVC device for air sterilisation.
➔ Condensate drain pan for horizontal installation.
➔ Back in view.
➔ Aesthetic and floor support feet.
➔ Formwork for recessed installation (only 2-pipe systems)
➔ Wall aesthetic panel for formwork, colour matt white RAL 9003.
➔ Ceiling aesthetic panel for formwork, colour matt white RAL 9003.
➔ Straight or 90° inlet fitting.
➔ 90° delivery fitting, insulated.
➔ Telescopic delivery fitting, insulated.
➔ Wall inlet grille made of aluminium, with straight profile.
➔ Wall delivery nozzle made of aluminium, with double row of adjustable fins.
➔ Ceiling inlet grille made of aluminium, with curved profile.
➔ Ceiling delivery nozzle made of aluminium, with curved profile.


STANDARD controls

For installation on machine
➔ Electronic board in combination with 3-speed thermostats
➔ Electronic board in combination with thermostats with 0-10V analogue output
For wall mounting installation
➔ Panel with room thermostat, summer/winter switch, speed switch and ON/OFF valve control.
➔ Electronic panel with automatic summer/winter switching for 2-pipe systems.


ADVANCED controls

➔ Slim-touch wall-mounted control panel, with RS485 Modbus RTU interface.
For installation on machine
➔❖ Touch control on board and electronic control with continuous speed modulation.
➔❖ Touch control on board and 4-speed electronic control, only for 2-pipe systems.
➔❖ Electronic control with continuous speed modulation only when combined with a KPST panel, with master/slave management up to 31 controls.
➔❖ RS485 Modbus RTU serial interface


Key: ❖ Factory fitted
➔ Supplied separately

BRIO-I SLIM - MVP-MVR-IXP-IVR
Total cooling capacity kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
Heating capacity only radiant function (50°C) MVR-IVR version kW
Heating capacity only radiant function (70°C) MVR-IVR version kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
W - MVP-MVR width mm
W - IXP-IVR width mm
H - MVP-MVR height - 2 pipes mm
H - IXP-IVR height - 2 pipes mm
H - MVP height - 4 pipes mm
H - IXP height - 4 pipes mm
Feet height /minimum height from floor mm
D - MVP-MVR depth mm
D - IXP-IVR depth mm
MVP-MVR weight - 2 pipes / MVP- 4 pipes kg
IXP-IVR weight - 2 pipes / IXP - 4 pipes kg
WxHxD - KCASE formwork - 2 pipes mm
10 20 25 30 40
0,99 1,83 2,89 3,34 3,98
0,76 1,35 2,17 2,44 2,91
0,39 0,73 1,15 1,27 1,47
0,98 1,81 2,87 3,31 3,94
0,75 1,35 2,16 2,43 2,9
0,38 0,73 1,14 1,27 1,46
1,13 2,03 3,19 3,75 4,57
0,81 1,48 2,32 2,75 3,19
0,57 0,75 0,92 1,48 1,84
1,38 2,48 3,91 4,59 5,57
0,99 1,8 2,84 3,35 3,89
0,7 0,92 1,11 1,8 2,24
2,27 4,08 6,41 7,54 9,17
1,63 2,98 4,67 5,52 6,42
1,16 1,54 1,84 2,97 3,7
0,32 0,38 0,46 0,55 0,66
0,54 0,67 0,78 0,92 1,08
0,67 1,21 1,76 2,3 2,84
0,56 0,97 1,27 1,81 2,3
0,33 0,69 0,95 1,31 1,45
0,77 1,42 2,16 2,74 3,3
0,63 1,15 1,55 2,18 2,7
0,36 0,8 1,12 1,58 1,71
162 320 461 576 648
113 252 367 453 494
55 155 248 370 426
50 51 52 54 54
42 43 45 46 46
32 33 34 35 34
41 42 43 45 45
33 34 36 37 37
23 24 25 26 25
11 19 20 28 35
9 10 13 15 17
7 7 7 8 8
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
10 20 25 30 40
723 923 1123 1323 1523
525 725 925 1125 1325
579 579 579 579 579
590 590 590 590 590
639 639 639 639 639
650 650 650 650 650
80 80 80 80 80
149 149 149 149 149
126 126 126 126 126
17 / 18 20 / 21 23 / 25 26 / 28 29 / 32
9 / 10 12 / 13 15 / 17 18 / 20 21 / 24
715x725x142 915x725x142 1115x725x142 1315x725x142 1515x725x142

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.