Fan coils with EC motor

DIVA-I

Cooling capacity: 2.8÷10.8 kW

Heating capacity: 3.4÷12.7 kW

WEBCODE: DIVI1 controls: ACREG

Product benefits

  • Consumption reduced by 50% compared to traditional motor
  • Set-ups for 2-, 4-pipe installations or 2 pipes with electrical resistance
  • ABS or metal ceiling panelling
  • 2 or 3-way, ON/OFF electrovalves and pre-mounted controls on board
Inverter_logo GreenLine_logo
  • IntCert1
  • CE_logo
  • Eurovent_logo

Cassette-type fan coil units



Construction features

• Fan coils: cassette-type for installation in false ceilings, with air return and delivery directly in the room.
• Heat exchanger: finned coil.
• Radial fan;
• Inverter brushless EC motor.
• Structure: self-supporting galvanised sheet steel complete with additional condensate drain pan and pump to lift the condensate (maximum head 650mm).
• PLP buffer ceiling (accessory): in ABS polymer (RAL 9003) with manually adjustable delivery fins, return grille and regenerable filter.


Type of system

• 2T - Boxes for 2-pipe systems.
• 4T - Boxes for 4-pipe systems.
• RE - Boxes for 2-pipe systems with supplementary electrical resistance.


Separately supplied accessories

• PLP-ABS ceiling panelling (RAL 9003).
• PLM-Metal ceiling panelling (RAL 9003) flush with false ceiling, 60x60cm models only.
➔❖ ON/OFF 3-way electrovalve for 2-pipe and 4-pipe systems.
➔❖ ON/OFF 2-way electrovalves for 2 and 4-pipe-systems.
• Primary air duct connection.
• Shank for air distribution at a distance from the unit.
• Primary air kit.


STANDARD controls

For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


iDRHOSS Controls

➔ Remote control and receiver.
➔ Electronic panel for wall mounting installation.
➔ Wall-mounted recessed electronic panel

For installation on machine
➔❖Master/slave electronic board, ON/OFF valve control module and electrical resistance, temperature probe for hot row.
➔ RS485 interface for serial communication with other devices (proprietary protocol; Modbus RTU protocol).
➔ RS485/USB serial converter
➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.
➔ KGTW-BAC- Gateway RS485/BACnet (max 64 fan coil).
➔ KGW-LON - Gateway RS485/FTT10-LonWorks (max 64 fan coil).

Key: ❖ Factory fitted
➔ Supplied separately

DIVA-I 2T - DIVA-I RE
Total cooling capacity kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
RE electrical resistance kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
Boxes - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Boxes - Weight kg
PLP Ceiling panelling - Weight kg
DIVA-I 4T
Total cooling capacity kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
Boxes - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Boxes - Weight kg
PLP Ceiling panelling - Weight kg
30 40 50 60 110
2,75 4,33 5,02 6,33 10,75
2,17 3,05 3,87 5,15 7,72
1,84 2,24 2,56 4,21 5,29
2,73 4,3 4,96 6,3 10,69
2,16 3,04 3,85 5,13 7,69
1,84 2,24 2,55 4,2 5,28
2,87 4,36 5,15 6,7 10,56
2,22 2,98 3,85 5,3 7,34
1,85 2,12 2,46 4,27 4,9
3,44 5,24 6,2 8,01 12,7
2,67 3,58 4,63 6,35 8,83
2,22 2,55 2,96 5,11 5,89
5,81 8,81 10,47 13,5 21,34
4,5 5,99 7,77 10,68 14,75
3,75 4,29 4,96 8,57 9,81
- 1,5 2,5 2,5 3
535 710 880 1165 1770
380 445 610 870 1130
310 310 360 630 710
47 54 60 48 57
39 43 50 39 47
33 33 37 33 34
38 45 51 39 48
30 34 41 30 38
24 24 28 24 25
16 31 62 33 108
8 11 21 17 32
5 5 7 10 10
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
30 40 50 60 110
575 x 275 x 575 820 x 303 x 820
670x 67x 670 965 x 85 x 965
22 24 24 36 39
3 3 3 6 6
30 40 50 60 110
2,77 3,93 4,53 6,51 9,87
2,18 2,81 3,53 5,28 7,17
1,85 2,09 2,38 4,3 4,98
2,75 3,9 4,47 6,48 9,76
2,17 2,8 3,51 5,26 7,14
1,85 2,09 2,37 4,29 4,97
3,18 2,91 3,29 8,24 8,33
2,51 2,2 2,66 6,65 6,27
2,13 1,73 1,92 5,41 4,58
3,62 3,35 3,79 9,36 9,51
2,85 2,53 3,06 7,54 7,16
2,43 1,98 2,2 6,14 5,22
535 710 880 1165 1770
380 445 610 870 1130
310 310 360 630 710
47 54 60 48 57
39 43 50 39 47
33 33 37 33 34
38 45 51 39 48
30 34 41 30 38
24 24 28 24 25
16 31 62 33 108
8 11 21 17 32
5 5 7 10 10
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
30 40 50 60 110
575 x 275 x 575 820 x 303 x 820
670x 67x 670 965 x 85 x 965
22 24 24 36 39
3 3 3 6 6

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12℃.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certificated performance.