Fan coils

VTNC

Cooling capacity: 2.9÷7.8 kW

Heating capacity: 3.7÷9.4 kW

WEBCODE: VTNC1 ACMEC

Product benefits

  • Boxes for 2-pipe systems
  • Adjustable motorised fins
  • Remote control (standard)
  • Wired panel
  • CE_logo
  • Eurovent_logo

Cassette-type fan coil units



Construction features

• Fan coils: cassette-type for installation in false ceilings, with air return and delivery directly into the room.
• Heat exchanger: finned coil.
• Fan: 3-speed.
• Structure: load-bearing, in galvanised sheet steel, complete with condensate drain pump (up to 200 mm above the unit) and auxiliary condensate drain pan.
• Buffer ceiling: in ABS polymer (RAL9010) with motorised delivery fins adjustable in various positions, return grille and regenerable filter.
• Remote control: supplied as standard.


Versions

VTNC - Boxes for 2-pipe systems


Separately supplied accessories

• 3-way ON/OFF electrovalve.
• 2-way ON/OFF electrovalve.
• Delivery nozzle lock.


STANDARD controls

For wall mounting installation
➔ Electronic panel for wall mounting installation.
➔ Centralised control panel for up to 64 units via serial connection, with daily and weekly time bands management.
➔ Serial interface for connection to control panel (proprietary protocol).

Key: ➔ Supplied separately


VTNC
Total cooling capacity kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
W2/H1/H2/D2 - Width 2/Height 1-2/Depth 2 mm
W/h1/h2/P - Width/Height/Depth mm
Weight kg
Ceiling panelling weight kg
26 36 46 60 85
2,91 3,59 4,37 5,8 7,83
2,54 3,05 3,5 4,86 6,94
2,17 2,69 2,96 4,04 6,04
2,86 3,52 4,28 5,64 7,66
2,5 3 3,45 4,76 6,8
2,14 2,65 2,92 3,95 5,92
3,1 4,25 4,48 5,81 7,92
2,71 3,61 3,55 4,21 7,02
2,37 3,21 3,03 3,23 6,63
3,65 4,95 5,31 6,89 9,42
3,2 4,2 4,25 5,21 8,37
2,8 3,73 3,62 4,1 7,77
6,2 8,52 9,09 11,82 16,21
5,46 7,31 7,42 8,92 14,59
4,84 6,56 6,34 6,93 13,8
560 690 840 1024 1460
490 540 570 733 1228
380 440 470 640 1041
54 59 63 56 64
47 52 56 51 58
41 46 48 45 56
45 50 54 47 55
38 43 47 42 49
32 37 39 36 47
50 70 90 156 170
40 50 50 105 140
30 40 40 92 120
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
26 36 46 60 85
575/265/285/575 575/265/285/575 575/265/285/575 840/230/245/840 840/300/315/840
647/50/30/647 647/50/30/647 647/50/30/647 950/50/35/950 950/50/35/951
18 18 18 29 35
3 3 3 6 6

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certificated performance.