Cassette fan coils with EC motor

DIVA-I

Cooling capacity: 2.7÷10.7 kW

Heating capacity: 3.4÷12.7 kW

WEBCODE: DIVI1 controls: ACREG

Product benefits

  • Consumption reduced by 50% with EC motor
  • Set-ups for 2 or 4-pipe installations or 2 pipe installations with electrical resistance
  • ABS or metal ceiling panelling with Coanda effect
  • New touch controls
  • 2 or 3-way, ON/OFF electrovalves and pre-mounted controls on board
Inverter_logo GreenLine_logo
  • IntCert1
  • CE_logo
  • Eurovent_logo

Cassette-type fan coil units.



Construction features

• Fan coils: cassette-type for installation in false ceilings, with air return and delivery directly in the room.
• Heat exchanger: finned coil.
• Radial fan;
• Inverter brushless EC motor.
• Structure: self-supporting, in galvanised sheet steel complete with an additional condensate drain pan and pump to lift the condensate (maximum head 650 mm).
• PLP buffer ceiling (accessory): in ABS polymer (RAL 9003) with manually adjustable delivery fins, return grille and regenerable filter.


Construction set-ups

Type of unit
2T - Single main coil
4T - Double main coil and additional
RE - Single main coil and supplementary electrical resistance.


ACCESSORIES

• PLP- ABS ceiling panelling (RAL 9003).
• PLM- Metal ceiling panelling (RAL 9003) flush with false ceiling, 60x60cm models only.

➔❖ 3-way ON/OFF electrovalve for 2 and 4-pipe systems.
➔❖ 2-way ON/OFF electrovalves for 2 and 4-pipe systems.
• Primary air duct fitting.
• Shank for air distribution at a distance from the unit.
• Primary air kit.


CONTROLS

STANDARD controls
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


Advanced LIT-TOUCH controls

➔ Wired LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ LIT-Touch remote control and receiver for ceiling panelling or wall mounting installation, with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔ Additional board with 2 digital outputs that can be configured.
➔ On board air temperature probe.
➔ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

DIVA-I 2T - DIVA-I RE
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
RE electrical resistance kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
Box - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Box - Weight kg
PLP Ceiling panelling - Weight kg
DIVA-I 4T
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) [EN1397] kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sp. sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
Box - Dimensions WxHxD mm
PLP Ceiling panelling - Dimensions WxHxD mm
Box - Weight kg
PLP Ceiling panelling - Weight kg
30 40 50 60 110
2,73 4,3 4,96 6,3 10,69
2,16 3,04 3,85 5,13 7,69
1,84 2,24 2,55 4,2 5,28
2,87 4,36 5,15 6,7 10,56
2,22 2,98 3,85 5,3 7,34
1,86 2,13 2,46 4,27 4,9
3,44 5,24 6,2 8,01 12,7
2,67 3,58 4,63 6,35 8,83
2,22 2,55 2,96 5,11 5,89
5,81 8,81 10,47 13,5 21,34
4,5 5,99 7,77 10,68 14,75
3,75 4,29 4,96 8,57 9,81
- 1,5 2,5 2,5 3
535 710 880 1165 1770
380 445 610 870 1130
310 310 360 630 710
47 54 60 48 57
39 43 50 39 47
33 33 37 33 34
38 45 51 39 48
30 34 41 30 38
24 24 28 24 25
16 31 62 33 108
8 11 21 17 32
5 5 7 10 10
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
30 40 50 60 110
575 x 275 x 575 575 x 275 x 575 575 x 275 x 575 820 x 303 x 820 820 x 303 x 820
670x 67x 670 670x 67x 670 670x 67x 670 965 x 85 x 965 965 x 85 x 965
22 24 24 36 39
3 3 3 6 6
30 40 50 60 110
2,75 3,9 4,47 6,48 9,76
2,17 2,8 3,51 5,26 7,14
1,85 2,09 2,37 4,29 4,97
3,18 2,91 3,29 8,24 8,33
2,51 2,2 2,66 6,65 6,27
2,14 1,74 1,92 5,41 4,58
3,64 3,38 3,85 9,39 9,62
2,86 2,54 3,08 7,56 7,19
2,44 1,99 2,21 6,15 5,23
535 710 880 1165 1770
380 445 610 870 1130
310 310 360 630 710
47 54 60 48 57
39 43 50 39 47
33 33 37 33 34
38 45 51 39 48
30 34 41 30 38
24 24 28 24 25
16 31 62 33 108
8 11 21 17 32
5 5 7 10 10
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
30 40 50 60 110
575 x 275 x 575 575 x 275 x 575 575 x 275 x 575 820 x 303 x 820 820 x 303 x 820
670x 67x 670 670x 67x 670 670x 67x 670 965 x 85 x 965 965 x 85 x 965
22 24 24 36 39
3 3 3 6 6

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12℃.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.

Performance refers to the motor’s input signal: 10V - 5V - 1V at MAX - MED - MIN speed.