Ducted fan coils with EC motor

YARDY-ID2

Cooling capacity: 2.4÷6.4 kW

Heating capacity: 3.0÷8.7 kW

WEBCODE: YAID2 ACMEC controls: ACREG

Product benefits

  • Consumption reduced by 50% compared to traditional motor
  • Continuous fan speed regulation
  • Quieter operation
  • Better room comfort
Inverter_logo GreenLine_logo
  • Canalizabile_logo
  • IntCert1
  • CE_logo
  • Eurovent_logo

Ducted fan coils for recessed horizontal or vertical installation.



Construction features

• Heat exchanger: with finned coil with left-hand connections reversible to right.
• Centrifugal fan: with inverter controlled electronic brushless motor and continuous speed regulation.
• Structure: made of galvanised sheet steel complete with natural condensate drain pan and regenerable filter.
• Standard or enhanced configuration setting by means of KCMI electronic board digital input.


Versions

• CXP - Recessed unit for horizontal or vertical installation (with lower return and upper delivery).


Accessories

➔❖ Additional water heating coil.
➔❖ Electrical resistance.
➔❖ Valve and lock.
➔❖ 2-way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 3-way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ Auxiliary condensate drain pan.
➔ Motorised damper.
➔ Frame with filter (G2) that can be extracted in any direction.
➔ Delivery straight fitting.
➔ 90° delivery and inlet fitting.
➔ Telescopic outlet/inlet fitting.
➔ Inlet grille with filter.
➔ Delivery grille.
➔ Flanged frame for connection to duct.
➔ Anti-vibration fitting for delivery/inlet duct connection.
➔ Intake/outlet plenum with round nozzles.


STANDARD controls

For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


iDRHOSS Controls

➔ Wall mounting receiver for remote control.
➔ Electronic panel for wall mounting installation.
➔ Wall-mounted recessed electronic panel

For installation on machine
➔❖ Master/slave electronic board, ON/OFF valve control module and electrical resistance, temperature probe for hot row.
➔ RS485 interface for serial communication with other devices (proprietary protocol; Modbus RTU protocol).
➔ RS 485/USB serial converter.
➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.
➔ KGTW-BAC- Gateway RS485/BACnet (max 64 fan coil).
➔ KGW-LON - Gateway RS485/FTT10-LonWorks (max 64 fan coil).

Key: ❖ Factory fitted
➔ Supplied separately

YARDY-ID2 CXP
Configuration (*)
Total cooling capacity kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) kW
kW
kW
Available static Air flow rate / Pressure m³/h / Pa
m³/h / Pa
m³/h / Pa
Delivery sound power dB(A)
dB(A)
dB(A)
Delivery sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - Width mm
H - Height mm
P - Depth mm
Weight kg
40 48 60 74 80 88
STANDARD ENHANCED STANDARD ENHANCED STANDARD ENHANCED STANDARD ENHANCED STANDARD ENHANCED STANDARD ENHANCED
2,42 3,08 2,65 3,35 3,37 4,22 3,9 4,68 4,75 6,02 5,1 6,4
2,05 2,76 2,28 3,01 3,09 3,58 3,57 4,5 3,84 5,42 4,3 5,8
1,2 1,2 1,29 1,29 1,59 1,59 1,73 1,73 2,04 2,04 2,3 2,3
2,36 3,01 E 2,58 3,28 E 3,29 4,12 E 3,81 4,58 E 4,65 5,88 E 5 6,26 E
2,01 2,7 E 2,24 2,95 E 3,03 3,5 E 3,5 4,42 E 3,79 5,32 E 4,25 5,7 E
1,19 1,19 E 1,28 1,28 E 1,58 1,58 E 1,72 1,72 E 2,03 2,03 E 2,29 2,29 E
2,57 3,29 E 2,6 3,34 E 3,84 4,73 E 3,83 4,77 E 5,66 7,37 E 5,75 7,48 E
2,16 2,93 E 2,17 2,97 E 3,47 4,53 E 3,46 4,48 E 4,62 6,6 E 4,65 6,71 E
1,16 1,16 E 1,18 1,18 E 1,58 1,58 E 1,61 1,61 E 2,49 2,49 E 2,5 2,5 E
3 3,86 3,06 3,94 4,46 5,52 4,55 5,63 6,58 8,55 6,71 8,72
2,54 3,44 2,59 3,51 4,05 5,23 4,13 5,33 5,39 7,69 5,5 7,84
1,39 1,39 1,42 1,42 1,9 1,9 1,94 1,94 2,92 2,92 2,98 2,98
5,1 6,56 5,19 6,65 7,72 9,44 7,81 9,62 11,3 14,72 11,54 14,93
4,31 5,84 4,38 5,92 7,02 9,04 7,07 9,1 9,3 13,21 9,47 13,42
2,35 2,35 2,39 2,39 3,24 3,24 3,27 3,27 5,1 5,1 5,13 5,13
2,29 2,76 E 2,18 2,62 E 3,57 4,16 E 3,39 4,32 E 4,55 5,71 E 4,33 5,43 E
2,01 2,52 E 1,92 2,4 E 3,3 3,99 E 3,15 3,7 E 3,89 5,11 E 3,69 5,03 E
1,28 1,28 E 1,22 1,22 E 1,91 1,91 E 1,91 1,91 E 2,42 2,42 E 2,3 2,3 E
2,59 3,12 2,46 2,96 3,94 4,61 3,74 4,78 5,04 6,32 4,79 6
2,3 2,86 2,19 2,72 3,67 4,43 3,49 4,10 4,35 5,68 4,13 5,59
1,47 1,47 1,4 1,4 2,2 2,2 2,19 2,19 2,78 2,78 2,64 2,64
350 / 70 469 / 64 E 350 / 70 469 / 64 E 573 / 61 737 / 56 E 573 / 61 737 / 56 E 767 / 76 1010 / 65 E 738 / 74 949 / 64 E
291 / 50 410 / 50 E 291 / 50 410 / 50 E 512 / 50 691 / 50 E 512 / 50 691 / 50 E 606 / 50 866 / 50 E 594 / 50 831 / 50 E
150 / 8 150 / 8 E 150 / 8 150 / 8 E 214 / 6 214 / 6 E 214 / 6 214 / 6 E 284 / 7 284 / 7 E 284 / 7 284 / 7 E
51 56 E 51 56 E 55 57 E 55 57 E 57 58 E 57 58 E
48 52 E 47 52 E 52 56 E 52 56 E 56 57 E 56 57 E
30 30 E 30 30 E 30 30 E 30 30 E 30 30 E 30 30 E
42 47 42 47 46 48 46 48 48 49 48 49
39 43 38 43 43 47 43 47 47 48 47 48
21 21 21 21 21 21 21 21 21 21 21 21
65 69 E 67 72 E 85 100 E 89 105 E 105 140 E 105 140 E
38 60 E 38 63 E 65 80 E 68 84 E 75 100 E 75 100 E
8 8 E 8 8 E 8 8 E 8 8 E 13 13 E 13 13 E
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
40 40 48 48 60 60 74 74 80 80 88 88
950 950 950 950 1250 1250 1250 1250 1250 1250 1250 1250
545 545 545 545 545 545 545 545 545 545 545 545
212 212 212 212 212 212 212 212 212 212 212 212
25,5 25,5 26,5 26,5 34,5 34,5 35,5 35,5 36,5 36,5 37,5 37,5

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

According to EN16583

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.

(*)

Performance refers to the following configurations: STANDARD: 2/6.5/8 Vdc outlet at min/med/max speed; ENHANCED: 2/7/10 Vdc outlet at min/med/max speed.

Yardy ID2 48 - 74 - 88 with oversized 4-row coil.

References

28 July 2017

Wasl Ballroom

UNITED ARAB EMIRATES

09 July 2017

Fortnum and Mason

UNITED ARAB EMIRATES

23 June 2017

Glitz Dubai

UNITED ARAB EMIRATES

12 December 2016

LEED Umberto Forti

ITALY