Ductable terminals
YARDY-HP
Cooling capacity: 7.2÷20.5 kW
Heating capacity: 9.6÷28.0 kW
WEBCODE: YAHP1 ACMEC controls: ACREG
Product benefits
- Horizontal and vertical installation
- New pan removable from below for cleaning
- Set up with 3, 4, 5-row coil
- Filters with different efficiency levels
- Remote control

Ductable terminals for recessed horizontal or vertical installation.
Construction features
• Structure: self-supporting, in galvanised sheet steel for horizontal installation in a false ceiling or vertical recessed wall installation, complete with natural condensate drain pan, flanges to fit to the inlet/delivery duct. Pan is removable from below. Filter supplied separately from the unit.
• Heat exchanger: with finned coil and electrical box for terminal block with reversible left connections, which can be switched right directly on site. Coil is removable from below.
• Double inlet centrifugal fan with directly coupled 3-speed motor. Fan unit is removable from below.
Versions
• CXP - Recessed unit for horizontal or vertical installation (with lower return to upper delivery)
Number of rows
• 3 Rows - Unit with 3-row coil; unit for recessed horizontal/vertical installation.
• 4 Rows - Unit with 4-row coil; unit for recessed horizontal/vertical installation.
• 5 Rows - Unit with 5-row coil (only models 250, 300); unit for recessed horizontal/ vertical installation.
Accessories
➔❖ Additional water heating coil (1 row) for 4T-KBAA 4-pipe systems - only for 3R units with a 3-row coil.
➔ External plenum with additional water heating coil for 4-pipe systems (PBAB).
➔❖ ON/OFF 2-way electrovalves for 2 and 4-pipe-systems.
➔❖ On/OFF 3-way electrovalves for 2 and 4-pipe-systems.
➔❖ Auxiliary condensate drain pan.
➔ Frame with filter that can be extracted in any direction (efficiency rating G1/ G2/G3).
➔ Straight delivery and inlet connection.
➔ 90° delivery and inlet fitting.
➔ Flange for connection to duct.
➔ Anti-vibration connection for connection to the inlet/delivery duct.
➔ Panel with round nozzles to be connected to the delivery/inlet connections.
STANDARD controls
For wall mounting installation
➔ Panel with speed and summer/winter switch.
➔ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electrical resistance.
➔ Electronic panel with automatic summer/winter switching for 2-pipe systems.
➔ Electronic panel with automatic summer/winter switching and automatic speed regulation for 2-pipe systems with electrical resistance or 4-pipe systems.
➔ Air probe with remote control option.
➔ Interface card to control up to 4 fan coils (models 100-150-200 only, for on board installation).
iDRHOSS Controls
➔ Wall mounting receiver for remote control.
➔ Electronic panel for wall mounting installation.
➔ Wall-mounted recessed electronic panel
For installation on machine
➔❖ Master/slave electronic board.
➔❖ Temperature probe for hot row.
➔❖ Module for ON/OFF valves and electrical resistance management.
➔ RS485 interface for serial communication with other devices (proprietary protocol; Modbus RTU protocol).
➔ RS 485/USB serial converter.
➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.
➔ KGTW-BAC- Gateway RS485/BACnet (max 64 fan coil).
➔ KGW-LON - Gateway RS485/FTT10-LonWorks (max 64 fan coil).
Key: ❖ Factory fitted
➔ Supplied separately
YARDY HP CXP | ||
❶ | Total cooling capacity | kW |
❶ | Total cooling capacity [EN1397] | kW |
❷ | Heating capacity (45°C) [EN1397] | kW |
❸ | Heating capacity (50°C) | kW |
❶ | Total cooling capacity | kW |
❶ | Total cooling capacity [EN1397] | kW |
❷ | Heating capacity (45°C) [EN1397] | kW |
❸ | Heating capacity (50°C) | kW |
❶ | Total cooling capacity | kW |
❶ | Total cooling capacity [EN1397] | kW |
❷ | Heating capacity (45°C) [EN1397] | kW |
❸ | Heating capacity (50°C) | kW |
❹ | Heating capacity of additional coil (70°C) | kW |
❺ | Heating capacity of additional coil (65°C) [EN1397] | kW |
❹ | Heating capacity of additional coil (70°C) | kW |
❺ | Heating capacity of additional coil (65°C) [EN1397] | kW |
❻ | Air flow rate/Speed static pressure (3R) | m³/h / Pa |
m³/h / Pa | ||
m³/h / Pa | ||
❼ | Delivery sound power (3R) | dB(A) |
dB(A) | ||
dB(A) | ||
❽ | Speed sound pressure (3R) | dB(A) |
dB(A) | ||
dB(A) | ||
Nominal spd absorbed power MAX | W | |
W | ||
W | ||
Maximum absorbed power (0 Pa) | W | |
Electrical supply | V-ph-Hz | |
DIMENSIONS AND WEIGHTS | ||
L - Width | mm | |
H - Height | mm | |
P - YARDY HP Depth | mm | |
P - PBAB Depth | mm | |
YARDY HP Weight | kg | |
100 | 150 | 200 | 250 | 300 |
7,16 | 8,37 | 10,13 | 13,53 | 15,22 |
6,96 | 8,13 | 9,75 | 12,85 | 14,42 |
8,37 | 10,22 | 12,56 | 17,02 | 19,5 |
9,66 | 11,71 | 14,28 | 19,12 | 21,82 |
8,41 | 9,51 | 11,37 | 16,55 | 18,75 |
8,22 | 9,28 | 11,04 | 15,88 | 18 |
9,31 | 10,92 | 13,33 | 19,59 | 22,61 |
10,86 | 12,68 | 15,38 | 22,35 | 25,76 |
- | - | - | 18,7 | 20,5 |
- | - | - | 18,04 | 19,75 |
- | - | - | 21,83 | 24,61 |
- | - | - | 25,04 | 28,11 |
6,69 | 6,78 | 9,35 | 10,44 | 11,31 |
6,09 | 6,22 | 8,61 | 9,86 | 10,74 |
12,9 | 14,14 | 16,4 | 29,73 | 32,77 |
11,56 | 12,69 | 14,78 | 26,92 | 29,68 |
1.552 / 60 | 1.840 / 60 | 2.339 / 60 | 3.312 / 60 | 3.875 / 60 |
1.369 / 50 | 1.620 / 50 | 1.717 / 50 | 2.189 / 50 | 3.075 / 50 |
1.013 / 35 | 1.432 / 35 | 1.414 / 35 | 1.329 / 35 | 2.415 / 35 |
61 | 62 | 62 | 63 | 68 |
59 | 61 | 60 | 59 | 64 |
56 | 59 | 57 | 55 | 61 |
47 | 48 | 48 | 49 | 54 |
45 | 47 | 46 | 45 | 50 |
42 | 45 | 43 | 41 | 47 |
200 | 245 | 380 | 680 | 800 |
190 | 230 | 330 | 670 | 750 |
- | - | - | 660 | 750 |
280 | 300 | 500 | 850 | 900 |
230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 |
100 | 150 | 200 | 250 | 300 |
1295 | 1295 | 1295 | 1295 | 1295 |
250 | 250 | 285 | 335 | 335 |
555 | 555 | 670 | 720 | 720 |
200 | 200 | 200 | 200 | 200 |
38 | 38 | 46 | 57 | 57 |
Data at the following conditions: |
|
❶ |
Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. |
❷ |
Air: 20°C - Water: 45/40°C. |
❸ |
Air: 20°C - Water: 50°C, flow rate as in cooling. |
❹ |
Air: 20°C - Water: 70/60°C. |
❺ |
Air: 20°C - Water: 65/55°C. |
❻ |
3 row coil (3R) without filter. |
❼ |
With G3 filter at the conditions specified in point 6 according to EN16583 |
❽ |
At 2 m from the air outflow point with directionality factor 2 and G3 filter. |