Low consumption WinPACK SE

TCAEY-THAEY 2110÷4340

Cooling capacity: 97.6÷328.6 kW

Heating capacity: 109.5÷354.6 kW

WEBCODE: WK011

Product benefits

  • High performance range with extended operating limits
  • Wide range of accessories
  • Compact version B for replacement markets
  • Multipurpose for systems with 2 pipes + DHW (with optional RC100)
  • Integrated MASTER/SLAVE control
IntCert5 GreenLine_logo AdesivoAfP_logo
  • SoloRaffr_logo
  • PdC_logo
  • Install_EST_logo
  • R410A_logo
  • CE_logo
  • Eurovent_logo
  • Bureau_Veritas_logo

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant.



Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 2, 3 or 4 capacity steps with high efficiency at partial loads.
Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels or finned coil with copper pipes and aluminium fins depending on models/sizes.
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load bearing structure made of galvanised and painted steel plate coated with polyester powders.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board.


Versions

• B -Standard version (TCAEBY-THAEBY).
• S - Silenced version complete with compressor technical compartment soundproofing, reduced speed fans (TCAESY-THAESY).


Models

• TCAEBY: standard unit designed for cooling only.
• TCAESY: silenced unit designed for cooling only.
• THAEBY: heat pump unit.
• THAESY: silenced heat pump unit


Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, including an automatic pump in standby. The pumps are available in the low or high head versions.
• TANK&PUMP with integrated buffer tank from 300 to 700 litres (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge.
• VPF control.
• Desuperheater.
• 100% heat recovery unit
• Electronic expansion valve.
• -10°C condensing control (standard in S versions).
• -15°C condensing control with fans with EC motor.
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Soundproofed compressor box or technical compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit delivery and intake valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Micro-channel coils with E-coating treatment.
• Copper/copper or copper/pre-painted aluminium coils.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery if applicable.
• Buffer tank integrative heaters
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.


Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.



TCAEBY-TCAESY MODEL
Nominal cooling capacity kW
Nominal cooling capacity kW
E.E.R.
E.E.R.
Absorbed power kW
Absorbed power kW
THAEBY-THAESY MODEL
Nominal heating capacity kW
Nominal heating capacity kW
C.O.P.
C.O.P.
Nominal cooling capacity kW
Nominal cooling capacity kW
Absorbed power kW
Absorbed power kW
TCAEBY-TCAESY-THAEBY-THAESY MODEL
TCAEBY sound pressure dB(A)
THAEBY sound pressure dB(A)
TCAESY sound pressure dB(A)
THAESY sound pressure dB(A)
TCAEBY sound power dB(A)
THAEBY sound power dB(A)
TCAESY sound power dB(A)
THAESY sound power dB(A)
Scroll/step compressor no.
Circuits no.
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
W - TCAEBY-TCAESY width mm
W - THAEBY-THAESY width mm
H - TCAEBY-TCAESY height mm
H - THAEBY-THAESY height mm
D - TCAEBY-TCAESY depth mm
D - THAEBY-THAESY depth mm
TCAEBY Weight kg
TCAESY Weight kg
THAEBY weight kg
THAESY weight kg
SEASONAL ENERGY PERFORMANCE
TCAEBY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
TCAESY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
THAEBY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
THAESY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
2110 2120 2140 2150 2170 2200 2220 4150 4170 4200 4220 4240 4270 4310 4340
106,5 114,4 127,4 147,3 165,2 188,1 212,1 146,3 166,4 189,2 213,2 229,2 256 299,9 328,7
102,5 110,4 122,4 142,3 159,2 183,2 205,1 142,3 161,4 182,3 207,2 224,2 250 291 319,7
2,81 2,79 2,8 2,81 2,81 2,8 2,8 2,99 2,9 2,83 2,92 2,8 2,8 2,81 2,76
2,72 2,67 2,65 2,71 2,7 2,66 2,7 2,93 2,82 2,67 2,82 2,68 2,66 2,68 2,61
37,9 41 45,5 52,4 58,8 67,2 75,8 48,9 57,4 66,9 73 81,9 91,4 106,7 119,1
37,7 41,3 46,2 52,5 59 68,9 76 48,6 57,2 68,3 73,5 83,7 94 108,6 122,5
2110 2120 2140 2150 2170 2200 2220 4150 4170 4200 4220 4240 4270 4310 4340
112,6 123,7 139,7 158,8 176,9 198 229,1 152,7 172,6 197,8 225,9 249 281,3 319,3 354,6
109,5 121,7 135,7 155,8 173,9 195,9 226 147,7 167,6 192,8 219,9 245 278,3 315,2 345,5
3,05 3,08 3,08 3,04 3,06 3,07 3,07 3,09 3,14 3,04 3,04 3,03 3,01 3,01 2,98
3,1 3,13 3,1 3,13 3,1 3,09 3,13 3,1 3,12 3,09 3,09 3,09 3,05 3,07 3,03
99,5 110,4 123,4 142,3 159,3 182,2 206,1 141,3 163,4 186,2 209,1 227,1 253,9 295,9 324,7
97,6 106,5 117,5 136,4 152,3 175,3 199,2 136,4 156,4 180,3 200,2 220,2 248 286,1 313,8
36,9 40,2 45,4 52,2 57,8 64,5 74,6 49,4 55 65,1 74,3 82,2 93,5 106,1 119
35,3 38,9 43,8 49,8 56,1 63,4 72,2 47,6 53,7 62,4 71,2 79,3 91,2 102,7 114
2110 2120 2140 2150 2170 2200 2220 4150 4170 4200 4220 4240 4270 4310 4340
55 56 56 57 58 58 59 57 57 57 58 60 60 60 61
53 54 54 55 56 56 57 54 54 56 56 58 60 60 61
49 50 50 51 52 52 53 51 51 51 52 54 54 56 57
49 50 50 51 52 52 53 50 50 52 52 54 55 56 57
87 88 88 89 90 90 91 89 89 89 90 92 92 92 93
85 86 86 87 88 88 89 86 86 88 88 90 92 92 93
81 82 82 83 84 84 85 83 83 83 84 86 86 88 89
81 82 82 83 84 84 85 82 82 84 84 86 87 88 89
2/3 2/3 2/2 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4
1 1 1 1 1 1 1 2 2 2 2 2 2 2 2
400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
2110 2120 2140 2150 2170 2200 2220 4150 4170 4200 4220 4240 4270 4310 4340
2650 2650 2650 3600 3600 3600 4550 3600 3600 3600 4550 4550 4550 4800 4800
2650 2650 2650 3600 3600 3600 4550 3450 3450 3700 3700 4800 4800 4800 4800
2440 2440 2440 2440 2440 2440 2440 2440 2440 2440 2440 2440 2440 2030 2030
2440 2440 2440 2440 2440 2440 2440 2000 2000 2030 2030 2030 2030 2030 2030
1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 2090 2090
1350 1350 1350 1350 1350 1350 1350 1520 1520 2090 2090 2090 2090 2090 2090
990 1000 1010 1160 1180 1180 1340 1165 1185 1190 1335 1670 1690 2400 2410
1110 1120 1130 1280 1300 1300 1460 1300 1320 1325 1470 1830 1850 2440 2450
1250 1310 1320 1470 1480 1565 1730 1450 1525 1725 1800 2375 2460 2580 2595
1250 1310 1320 1470 1480 1565 1730 1475 1550 1765 1840 2415 2500 2620 2635
2110 2120 2140 2150 2170 2200 2220 4150 4170 4200 4220 4240 4270 4310 4340
106,5 114,4 127,3 147,2 165,2 188,1 212 146,3 166,4 189,2 213,1 229,2 256 299,9 328,6
3,85 3,87 3,89 3,84 3,91 4 3,89 4,05 4,09 4,09 4,12 4,04 4,1 4,02 4,03
151 152 153 150 153 157 153 159 161 161 162 159 161 158 158
102,5 110,4 122,4 142,3 159,2 183,2 205,1 142,3 161,4 182,3 207,2 224,2 250 291 319,7
3,92 3,94 3,93 3,96 3,95 4 3,96 4,15 4,15 4,03 4,16 4,06 4,07 4,07 4,03
154 155 154 155 155 157 155 163 163 158 163 159 160 160 158
95 104 119 134 149 170 200 129 145 168 192 211 240 271 301
3,38 3,4 3,67 3,36 3,63 3,34 3,53 3,41 3,47 3,33 3,33 3,35 3,34 3,35 3,32
132 133 144 131 142 131 138 133 136 130 130 131 130 131 130
92 102 115 131 146 167 197 125 140 164 187 207 238 267 292
3,47 3,49 3,71 3,5 3,72 3,39 3,62 3,42 3,46 3,4 3,4 3,44 3,39 3,41 3,37
136 136 145 137 146 133 142 134 135 133 133 135 133 133 132

Data at the following conditions:

Air: 35°C - Water: 12/7°C.

Air: 7°C, D.B. 6°C W.B.- Water: 40/45°C.

In open field (Q = 2) at 10 m from the unit.

Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.

Weight referred to the unit without load and not accessorised.

TCAESY-THAESY silenced versions.

Performance according to EN 14511:2013.

Low temperature application (7°C)

Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

In Average climatic conditions, low temperature application (35°C)

Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/213 and No.813/2013)

References

27 October 2017

Università di Milano

ITALY

30 June 2017

Leisnig Kerateam

GERMANY

22 February 2016

BuS Elektronik GmbH & Co. KG

GERMANY

05 May 2015

UNAC Cpy

FRANCE