Heat recovery unit

UTNR-HE Platinum 040÷400

Air flow rate: 310÷4.250 m³/h

WEBCODE: UTHE3

Product benefits

  • Compliant with ErP 2018 NRVU
  • Very high efficiency heat recovery Eurovent Certificate
  • Multi-speed or Brushless EC fans
  • F7 and M5 high efficiency filters
  • Double sandwich wall with high insulation capacity
  • Full control kit
Inverter_logo GreenLine_logo
  • Install_INT_logo
  • Install_EST_logo
  • Canalizabile_logo
  • IntCert1
  • IntCert4
  • CE_logo

Fresh air terminal unit with enthalpy rotary heat recovery.



Construction features

• Recovery unit: high yield rotary type made of aluminium with hygroscopic surface. Electric induction motor with belt and pulley transmission. Recovery unit-motor assembly easily removed from the side for periodic maintenance.
• Fans: fresh air inlet and forward blade double intake centrifugal expulsion type with a continuously adjustable directly coupled electric motor; optionally, EC Brushless technology high efficiency electric motors. Fan unit installed on anti-vibration mountings to prevent the transmission of vibration to the structure. The EC fans can be factory set for operation with constant flow (specification to be provided in order)
• Structure: frame made with extruded aluminium profile with preloaded nylon joints. Sandwich buffer panels, 23 mm thick, with galvanised sheet steel on the inside and pre-painted on the outside with thermal and acoustic insulation made of injected polyurethane, with a density of 45 kg/m3.
• Integrated free cooling or thawing by-pass system. Thanks to the presence of a motorised damper on the heat recovery side, a bypass system can be created to manage the freecooling or thawing depending on requirements or mm thermohygrometric conventions, with galvanised sheet steel on the inside and pre-painted on the outside with thermal-acoustic insulation made of injected polyurethane, with a density of 45 kg/m3 offering very high thermal and acoustic insulation.
• Filtering section: filtration sections made of compact cell filters with low pressure drop polypropylene media, removable from the side, with F7 efficiency class in fresh flow and M5 in expulsion flow.
• Factory-installed dirty filter differential pressure switches
• Terminal block: already part of the machine to facilitate the electrical connections, fan controls and rotary recovery.


Versions

• UTNR-HE/O PLATINUM - Recovery unit with rotary heat exchanger, installed horizontally and with standard multi-speed fans
• UTNRE-A/O PLATINUM - Recovery unit with rotary heat exchanger, installed horizontally and with Brushless EC fans that reduce the power consumption for ventilation at equal performance.

Available orientation
• 01 - Right-hand connections
• 02 - Left-hand connections
The selected orientation must be specified to process the job order.

Installation
• EXT- Outdoor installation


Factory fitted accessories

• ERF7-F7 efficiency return filter
• BP-Bypass control for free-cooling including: NC relay on board the panel (suitable for PCU and KPCUE) and 2 NTC probes on board the machine


Separately supplied accessories

• KBER - Reheating electrical resistance installed outside in a duct dedicated module, complete with filament-type safety thermostats and control relays to contain pressure drops.
230/1/50 single-phase electrical supply for model 040 and 075. 400/3/50 three-phase for 100÷400 models.
• KSBFR - Section containing hot/cold water coil to reheat or recool, placed outside the machine in front of the inlet. Includes stainless steel condensate drain pan with drain connection from the bottom.
• KSBFR + ATG - Hot/cold water coil section with mounted antifreeze thermostat
• KSRE - Regulation damper preset for servo-control, consisting of a galvanised sheet steel frame with adjustable fins.
• KSSC - Duct silencer with a rectangular base made of glass wool covered with a protective film of glass fibre and micro-stretched sheet steel.
• KRMS - Section with 3 dampers for air mixing and recirculating (only for horizontal installation).
• KSPC - Panel with round fittings.


Controls

• KCV2-Speed selector for wall mounting installation, to select from 3 speeds (excluding model 40): Off/heating/cooling switch; 3-speed switch; 230V power supply.
• PCU-KPCUE - Control panel for wall mounting installation, allows the winter/summer room temperature to be controlled, gives consent to activate or exclude the water coil or the electrical resistance. Selects the operating speed of the fan from minimum, medium, maximum (excluding model 40 which only offers one speed) or by 0/10 V regulation (KPCUE for EC fans) and controls the free-cooling function.
• KPTZ - Rotating potentiometer for wall mounting installation, dedicated to manual fan speed control. The speed of delivery and return fans is calibrated with a single potentiometer (only for the EC Brushless fan version).

Full Controls
• KRFCS - Electrical panel complete with: DDC programmable microprocessor regulator. BMS interfacing Integrated as standard with Modbus RTU protocol, main disconnecting switch, relay to control various users, terminal blocks for quick connection of all machine components, auxiliary circuit supply with suitable transformer 230/12-24V.

Optional first start-up


User panels (for KRFCS)
• KHMIG -Interface terminal with black monochrome graphic display with LED backlighting.
• KHMIR - Interface terminal complete with integrated room temperature probe with black monochrome graphic display with LED backlighting.
• KTOUCH - Black and white touch screen control panel.
• KCOLOR - Colour touch screen control panel.
• KCW - White decorative plate for control panel.
• KCB - Black decorative plate for control panel.
• KWMS - Wall mounting installation support for control panel.

Valves and actuators
• KV3V - PN40 Mixer/diverter 3-way regulation ball valves, female threaded hydraulic connections.
• KV2V - PN40 2-way regulation ball valves, female threaded hydraulic connections.
• KVMM - Actuator for ball regulation valves with modulating control 0/10 Vdc 24 Vac power supply.
• KV0M - Actuator for 230V On/Off valves.
• KDMA-S - Actuator for modulating damper 0-10V 24V with spring return.
• KDMA - Actuator for modulating damper 0-10V 24V without spring return.
• KDOA - Actuator for ON/OFF damper with spring return.
All the probes, actuators and valves on the Full Control section are also available.


UTNR-HE PLATINUM MODEL
Type of Unit
Outdoor air filters
Return air filters
Bypass
TECHNICAL SPECIFICATIONS
Nominal air flow m³/h
STANDARD FANS
Nominal available static pressure Pa
Specific fan power (SFP) W/(m3/s)
Sound pressure level dB(A)
Speed N°/Regulation Type
Electrical supply V-ph-Hz
BRUSHLESS EC FANS
Nominal available static pressure Pa
Max available static pressure Pa
Specific fan power (SFP) W/(m3/s)
Sound pressure level dB(A)
Speed N°/Regulation Type
Electrical supply V-ph-Hz
COUNTERFLOW HEAT RECOVERY
Winter efficiency temp/enthalpy %
Summer efficiency temp/enthalpy %
Efficiency Regulation EC 1253/2014 %
DIMENSIONS AND WEIGHTS
Length/Height/Depth UTNR-A PLATINUM mm
Weight kg
40 75 100 150 200 320 400
Non-residential- Bidirectional
F7
M5
Motorisable side bypass damper
310 640 1000 1650 2400 3200 3800
230 130 190 160 300 180 n.d.
1409 1443 1580 1036 806 1226 n.d.
59 60 62 62 63 66 n.d.
4 3 3 3 3 3 n.d.
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
230 130 190 160 300 180 100
430 280 560 600 480 460 230
1045 1263 1102 842 617 869 1029
60 61 61 63 62 65 66
0-10 V
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
79/74 74/69 73/58 74/60 75/62 74/60 73,5/59
79/69 74/65 73/59 75/60 81/65 75/59,5 73/59
74,2 74 73 73 73,7 74,3 73
40 75 100 150 200 320 400
1075/480/800 1075/480/800 1205/550/1000 1400/550/1000 1720/680/1290 2000/680/1400 2000/680/1400
70 75 105 140 180 230 250

Data at the following conditions:

Values referred to the nominal air flow considering the pressure drops of the heat recovery and the F7 filter

Values referred to the nominal air flow and Nominal available static pressure

Sound pressure level referring to 1 m from the machine inlet in free field

Outdoor air T: -5°C, 80% RH ; Ambient air T: 20°C, 50% RH.

Outdoor air T: 32°C, 50% RH ; Amb. air T: 26°C, 50% RH.

Dry nominal conditions, measured according to En 308 in balanced flows. Outdoor air 5°C D.B.; Ambient air 25°C D.B.